Ashrava recognizes that downtime is not an option for your servers. That's why we continually improve our hardware and facilities to ensure that you are up and running, 24 hours a day, seven days a week.

Location

The Ashrava Data Center is located in Baltimore, Maryland, part of the greater Washington-Baltimore technology corridor and near the I-95 highway and Baltimore-Washington International Airport. The Data Center is easily accessible from cities all over the East Coast. Located in the heart of Baltimore's downtown area and financial district, the Data Center is located on a redundant power grid that has three power stations. Two major banks are also relying on this power grid.

Security

The security of the Data Center is a top priority for Ashrava. We have taken extreme care to implement the most stringent security measures so our customers can rest easy knowing their data is safe. The Data Center is located in a heavily protected building with security personnel on guard 24 hours a day, 7 days a week. Other security features include biometric fingerprint readers on door locks and fire protection by Pre-Action Fire Sprinkler and Halon System.

Cooling

The Data Center is monitored around the clock by ADT's state-of-the-art temperature sensors. Air temperature is maintained at an optimal 65 degrees Fahrenheit. Large fans pull filtered air into each server's protective case, ensuring that dust and particles remain safely outside the server. The cooling system includes 44 tons of chilled-water cooling, 40 tons of air-chilled cooling, and two 10 ton portable Liebert industrial air conditioners maintaining optimal temperature over 5,000 square feet of raised flooring.

Preparation

Our internally-developed monitoring system keeps a constant check on the health of your servers, notifying us in advance of any potential problems. If something unforeseen does occur, the Data Center is prepared. There are redundant hot swap power supplies for each server. If a power supply fails, the server keeps running with power from the alternate supply while alarms alert technicians who quickly restore redundancy. Due to this preparation, servers and client sites experience no downtime. In the unlikely event of power outage on the 3 tier Baltimore Gas & Electric power grid, our automatic transfer switches activate the backup power system consisting of a 300 kVW diesel generator. The diesel generator can run indefinitely until outside power is restored.

 

Ashrava Datacenter Details..

Physical Details

  • Located in the heart of downtown Baltimore's business district
  • Encompasses more than 6,000 square feet of raised flooring
  • Features Pre-Action fire suppression system
  • Secured by building security and biometric fingerprint access scanners
  • Recorded log of visitor and employee entry

Power Details

  • Connecting to an extensive Baltimore Gas & Electric 3-tier redundant power grid
  • Possesses 300 kVW Genrac diesel generator
  • 130 Kva PowerWare UPS
  • 80 Kva MGE UPS
  • Two 50 kVA Liebert UPS
  • Multiple automatic transfer switches (ATS)
  • Redundant power feeds to our Data Center

Industrial Grade Cooling

  • 44 tons of chilled-water cooling
  • 40 tons of air-chilled cooling
  • 35 tons of Liebert industrial air conditioners
 